WALLS:
Vertical structures in buildings must carry heavy loads safely. Loads resulting from the structure's own weight, ceilings, roof and wind pressure as well as shock loads from the internal and external environment.
An equally important requirement is fire resistance, good heat and sound insulation and heat accumulation. Also important is non-absorbability and water resistance, while maintaining breathability, and finally another important factor is the attractive appearance, durability and ease of maintenance of the building.
Static properties of the VELOX building system depend on the resistance of the concrete core, which transmits all vertical loads. The VELOX Custom shuttering plates together with the perimeter walls serve as thermal insulation. The internal load-bearing walls contribute to the improvement of sound insulation. Other properties of the boards (fire resistance, adhesion of plasters, non-absorbability, and breathability) give the walls their unquestionable quality.
- Good heat and sound insulating properties
- High tensile strength and flexibility
- Excellent adhesion of concrete and plaster
- Simple and solid nailing plates
- Shock resistance from 50 mm
- Healthy and hygienic
- Resistant to animals and plant pests
- Good fire resistance

Board type and thickness as marked "d" | VELOX WS | |||
25mm | 35mm* | 50mm | ||
TECHNICAL FEATURES | Unit | VALUES | ||
Standard board dimensions (length width lxb) |
mm | 2000 x 500 | 2000 x 500 | 2000 x 500 |
The average basis weight ** | kg / m² | 19 | 25 | 33 |
The average bulk density ** (as of 4 070-022943 10th 2004) |
kg / m³ | 700 | 670 | 630 |
Thermal conductivity λ 90/90 **** | W / mK | 0.11 | 0.11 | 0.11 |
Thermal resistance R 90/90 *** | m² K / W | 0.22 | 0.33 | 0.45 |
Diffusion resistance factor μ (according to the 9/97 of 14 2nd 1997) |
- | 13.7 | 13.7 | 13.7 |
Tensile strength in bending (PN 3-03 dated 1 8th 2003) |
N / mm ² | ≥ 1.8 | ≥ 1.3 | ≥ 1.0 |
Request health and hygiene safety | - | Safety Data Sheet (MIT Decree No. 231/2004 Coll.) |
||
Reaction to fire (according PKO-07-115/AO 204) | - | A2-s1, d0 |
* The boarding the outside perimeter wall plate is supplied WSC in red
** Tolerance ± 10%
*** according to DIN EN 13168
**** Measured value
- Good heat and sound insulating properties
- High tensile strength and flexibility
- High adhesion of concrete and plaster
- Simple and solid nailing plates
- Shock resistance for thick plates. 35 and 50 mm
- Healthy and hygienic
- Resistant to animals and plant pests
- Good fire resistance

Board type and thickness as marked "d" | VELOX WSD | |||
25mm | 35mm | 50mm | ||
TECHNICAL FEATURES | Unit | VALUES | ||
Standard board dimensions (length width lxb) |
mm | 2000 x 500 | 2000 x 500 | 2000 x 500 |
The average surface density * | kg / m² | 21 | 29 | 40 |
The average bulk density * (PN 3-03 dated 1 8th 2003) |
kg / m³ | 790 | 790 | 790 |
Thermal conductivity λ n (according Architektenordner MR) |
W / mK | 0.15 | 0.15 | 0.15 |
Thermal resistance R 90/90 ** (design value of 6 3rd 2007) |
m² K / W | 0.167 | 0.233 | 0.333 |
Diffusion resistance factor μ (according Architektenordner MR) |
- | 15 | 15 | 15 |
Tensile strength in bending (PN 3-03 dated 1 8th 2003) |
N / mm ² | ≥ 2.9 | ≥ 2.2 | ≥ 1.8 |
Request health and hygiene safety | - | Safety Data Sheet (MIT Decree No. 231/2004 Coll.) |
||
Reaction to fire (according PKO-07-115/AO 204) | - | A2-s1, d0 |
* Tolerance ± 10%
** according to DIN EN 13168
- Excellent thermal and sound insulation properties
- Excellent adhesion of concrete and plaster
- Simple and solid nailing boards
- Simple creation of corners and lining
- Shock resistant
- Healthy and hygienic
- Resistant to animals and plant pests
- Good fire resistance

Board type and thickness as marked "d" | VELOX WS EPS | ||||||
185 | 155 | 135 | 115 | 95 | 85 | ||
Thickness of layer plate (mm) | VELOX WS | 35 | 35 | 35 | 35 | 35 | 35 |
Expanded polystyrene | 150 | 120 | 100 | 80 | 60 | 50 | |
TECHNICAL FEATURES | Unit | VALUES | |||||
Standard board dimensions (length width lxb) |
mm | 2000 x 500 | |||||
The average surface density * | kg / m² | 29 | 29 | 28 | 28 | 27 | 27 |
Thermal conductivity λ 90/90 ** plate VELOX WS 35 (the weight of moisture w m = 6%) (According 070-022449 of 30 4th 2004) |
W / mK | 0.11 | 0.11 | 0.11 | 0.11 | 0.11 | 0.11 |
Thermal conductivity λ D of polystyrene |
W / mK | 0,038 | 0,038 | 0,038 | 0,038 | 0,038 | 0,038 |
Thermal resistance R (According HSZ-07-28 / T, June 2007) |
m² K / W | 4.27 | 3.48 | 2.95 | 2.42 | 1.90 | 1.63 |
Diffusion resistance factor ¾ expanded polystyrene boards (Protocol No. 1145 of 18 6th 2004) |
- | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 |
Request health and hygiene safety | - | Safety Data Sheet (MIT Decree No. 231/2004 Coll.) |
|||||
Reaction to fire (according PKO-07-115/AO 204) | - | A2-s1, d0 |
* Tolerance ± 10%
of
measured value **
NOTE: Technical characteristics of polystyrene based on the classification of its properties according to EN 13,163th. Depending on the order, we can supply WS-EPS boards in combination with other manufactured thicknesses of expanded polystyrene (EPS WS-75, 105, 125, 215, 235).
- Excellent thermal and sound insulation properties, suitable for construction of passive houses
- Excellent adhesion of concrete and plaster
- Simple and solid nailing boards
- Simple creation of corners and lining
- Shock resistant
- Healthy and hygienic
- Resistant to animals and plant pests
- Good fire resistance

Board type and thickness as marked "d" | VELOX WS EPS plus | |||||||
235 | 215 | 185 | 155 | 135 | 115 | 85 | ||
Thickness of layer plate (mm) | VELOX WS | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
Expanded polystyrene | 200 | 180 | 150 | 120 | 100 | 80 | 50 | |
TECHNICAL FEATURES | Unit | VALUES | ||||||
Standard board dimensions (length width lxb) |
mm | 2000 x 500 | ||||||
The average surface density * | kg / m² | 30 | 30 | 29 | 29 | 28 | 28 | 27 |
Thermal conductivity λ 90/90 ** plate VELOX WS 35 (the weight of moisture w m = 6%) (According 070-022449 of 30 4th 2004) |
W / mK | 0.11 | 0.11 | 0.11 | 0.11 | 0.11 | 0.11 | 0.11 |
Thermal conductivity λ D of polystyrene |
W / mK | 0,032 | 0,032 | 0,032 | 0,032 | 0,032 | 0,032 | 0,032 |
Thermal resistance R (According HSZ-07-28 / T, June 2007) |
m² K / W | 6.57 | 5.94 | 5.01 | 4.07 | 3.44 | 2.82 | 1.88 |
Diffusion resistance factor ¾ expanded polystyrene boards (Protocol No. 1145 of 18 6th 2004) |
- | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 | ≥ 29 |
Request health and hygiene safety | - | Safety Data Sheet (MIT Decree No. 231/2004 Coll.) |
||||||
Reaction to fire (according PKO-07-115/AO 204) | - | A2-s1, d0 |
* Tolerance ± 10%
of
measured value **
NOTE: Technical characteristics of polystyrene based on the classification of its properties according to EN 13,163th. Depending on the order, we can supply WS-EPS Plus boards in combination with other manufactured thicknesses of expanded polystyrene (EPS WS-75, 105, 125, 215, 235).
The VELOX reveal strips are precisely cut to 50mm thickness and are used to create the horizontal and vertical door and window jambs in supporting walls.
The lane width varies according to the choice and composition of the wall and is determined by the thickness of the fill between the Velox boards. For example, the combined thickness of the concrete core and expanded polystyrene.

VELOX - REVEAL STRIPS | ||||
TECHNICAL FEATURES | Unit | VALUES | ||
Length of the strip l | mm | 2000 | 2000 | 2000 |
The thickness of the strip b | mm | 50 | 50 | 50 |
Lane width d | mm | up to 165 | from 166-248 | from 249-340 |
The average weight* | kg/m | 6 | 9 | 12 |
* Tolerance ± 10%
To determine the consumption of marginal strips on the construction of the empirically considering a consumption of about 0.5 m / m 2 and the outer wall about 0.3 m / m 2 interior load-bearing walls.
VELOX insulated reveal strips are based on precisely cut boards of VELOX WS with thickness of 50 mm (standard reveal strips).
They also carry polystyrene insulation thickness of 100 mm and 150mm wide, so that it is possible to fit the insulation in a standard Velox wall with a concrete core of 150 mm.
- Improving thermal insulating properties
- Prevention of thermal bridges
- Used for low energy and passive houses

VELOX - INSULATED REVEAL STRIPS | ||||
TECHNICAL FEATURES | Unit | VALUES | ||
Length of the strip l | mm | 2000 | 2000 | |
The thickness of the strip b | mm | 50 | 50 | |
Lane width d | mm | from 166-248 | from 249-340 | |
Insulation Width | mm | 150 | 150 | |
Insulation Thickness | mm | 100 | 100 | |
The average weight* | kg/m | 9.5 | 12.5 |
* Tolerance ± 10%
To determine the consumption of marginal strips on the construction of the empirically considering a consumption of about 0.5 m / m 2 and the outer wall about 0.3 m / m 2 interior load-bearing walls.
Structure of fixing ties with welded crossbars.
They ensure fixation of board position in outside and inside casing of walls, also serving to lay and join of each casing board on each other in vertical position of both coating.
- Produced from tow wire and made of steel 11 343, Velox building ties have a diameter of between 4 and 5 mm, including welding. They fulfill the required strength in tow 540 MPa
- Standard surface treatment is applied under the plaster
- The width of the ties vary and depends on the combination of each layer of a wall
- When used without plaster, it is possible to paint the surface with a special treatment.

Available ties according to shape and usage:
One side ties - Usually laid in the bottom level of the first layer of casing, at ceiling level, on the inside of supporting walls and when windowsills are built.
Both-side ties - Placed frequently when laying and tieing each board of wall.
Ceiling ties - Placed on the same level as ceiling, the ceiling tie is laid on the peripheral, supporting wall with one end of the tie on inside the casing and the other one on the already drilled holes of connecting boards where it is fixed, with nails, on the end eye.
Tow ties - Run through pre-drilled holes in the center of the end eye of the outside boards and inside boards of casing. The end eye is fixed with nails. When using VELOX WS boards, it is recommended that you use 2 or 3 rows of casing boards so that the strength of the casing will increase during the concreting of the whole floor.
Second clip | Staple length (mm) (Wall thickness) |
CONSUMPTION | PROFILE | |
Exterior wall | Interior wall | |||
One side | 150-400 | 5pcs/m* walls | 8pcs/m** wall | ![]() |
Both sides | 150-400 | 4pcs/bm joints | 4pcs/bm joints | ![]() |
Ceiling | 150-400 | 4pcs/m wall | - | ![]() |
Tow | 150-400 | 1-2pcs/bm one layer formwork | 1-2pcs/bm one layer formwork | ![]() |
- Used to ensure the verticalness of walls
- They are placed, depending on requirements, inside the formwork ( normally every 2 m, or either side of openings)
- They are manufactured from high quality steel 10505 and are available in lengths of 2,800, 3,000, 3,200 and 4,000 mm

- Used with ceiling modules to reinforce rib ceilings (placed between each ceiling module spanning from supporting wall to wall)
- Used for reinforcement above openings (doors/windows)
- Door/windows overlapping the clear span by 150mm either side)
- Available sizes are specified below
- Made of Steel group R10 505

Permanent loading of ceilings | Standard (Kn/m2) | Co-efficient | Computational |
1. Ceiling element VELOX - Thickness of ceiling make up | |||
170 + 50 = 220mm | 0,53 | 1,10 | 0,58 |
220 + 50 = 270mm | 0,57 | 1,10 | 0,63 |
260 + 50 = 310mm | 0,59 | 1,10 | 0,65 |
2. Concrete and reinforcement for given ceiling thickness | |||
170 + 50 = 220mm | 2,12 | 1,10 | 2,33 |
220 + 50 = 270mm | 2,42 | 1,10 | 2,66 |
260 + 50 = 310mm | 2,66 | 1,10 | 2,93 |
Standard loading | |||
Ceramic tiles 10mm - 0,01*23 | 0,23 | 1,10 | 0,25 |
2. Concrete screed 40 mm - 0,04*23 | 0,92 | 1,30 | 1,20 |
3. Insulation against impact noise (Fibrex) - 0,02*1,2 | 0,02 | 1,20 | 0,03 |
4. Plaster 20 mm - 0,02*19 | 0,38 | 1,30 | 0,49 |
Total | 1,55 | 1,27 | 1,97 |
Utility standard loads | |||
1. Loading of flats | 1,50 | 1,40 | 2,10 |
Total | 1,50 | 1,40 | 2,10 |
Overall standard loading of ceilings for given ceiling thickness | |||
170 + 50 = 220 mm | 5,70 | 1,22 | 6,99 |
220 + 50 = 270 mm | 6,04 | 1,22 | 7,36 |
260 + 50 = 310 mm | 6,30 | 1,21 | 7,65 |
* Web with 120mm
Suitable for creating interior non-bearing partition walls (single, double, combined).
They are manufactured in two basic thicknesses of 75 and 100 mm, and by gluing together two VELOX WS boards.
The resulting product is a solid partition with a thickness of 75 or 100 mm.
- Simple, quick and dry construction walls
- Connecting panel joints with polyurethane foam mounting or suitable adhesives, respectively.
- Partitions are achieved even after making the final strength (short curing time of fasteners)
- Healthy and hygienic
- High fire resistance
- Excellent adhesion of plasters

Board type and thickness as marked "d" | PARTITION WALL PLATES VELOX | ||
75mm | 100mm | ||
TECHNICAL | Unit | VALUES | |
idth lx b) | mm | 2000 x 500 | 2000 x 500 |
The average surface density * | kg / m2 | 53 | 68 |
Thermal resistance R (according Architektenordner MR) | m 2 K / W | 0.79 | 0.90 |
Diffusion resistance factor μ (according Architektenordner MR) | - | 9 | 9 |
Request health and hygiene safety | - | Safety Data Sheet (MIT Decree No. 231/2004 Coll.) | |
Airborne sound insulation | dB | 39 (37/2001 of 23 3rd 2001) | 39 (Evaluation Sound. izol. properties of partitions VELOX of May 24, 1999) |
Reaction to fire (according PKO-07-115/AO 204) | - | A2-s1, d0 |
Soundproofing of non-bearing VELOX partition walls are intended for use in rooms where the requirement for sound insulation is a minimum of 42 dB. Partition walls are created by a combination of two VELOX WS 25 boards sandwiching acoustic mineral wool.
A standard partition board's size is 2000 x 500 x 100 mm.
VELOX Partition boards can be used in any of the building systems currently available. Installation of partition walls starts by marking individual walls and openings. After the walls, floors and ceilings are marked, UW profiles 100 mm are fixed using suitable fasteners. For better sound insulation, it is possible to lay the profiles onto foam insulation tape. VELOX partition boards are then fitted into these profiles and adhered by low expanding polyurethane foam.
The openings for windows/doors are framed again by UW 100 profiles. Lintel opening is also formed by using profile UW 100. Partition boards are laid in a brick pattern with a minimum overlap of 600 mm. For structural reasons, we recommend solid walls (without openings) to be supported every 5 meters with two UW 100 profiles with inserted insulation tape in between.
Surface treatment is recommended to perform in accordance with the design schedule (plasterboard or plaster) in thickness min. 15mm.

Board type and thickness | PARTITION WALLS VELOX | |
TECHNICAL FEATURES | Unit | 100mm |
Standard board dimensions (length width lxb) |
mm | 2000 x 500 |
Weight | kg / m² | 55 |
Diffusion resistance | m² K / W | 1,84 |
Request health and hygiene safety | - | 231/2004 SB.) |
Airborne Sound | dB | 49 |
Reaction to fire (according PKO-07-115/AO 204) | - | B-s1, d0 |
WALL STRUCTURES:
It is possible to build passive houses thanks to the excellent properties of VELOX building systems.
The overall concept of a passive house must take into account the need for consistently low energy consumption making VELOX an ideal solution.
The low demand for heating of houses built with VELOX technology are the result, not only of the excellent thermal insulation properties of walls with optional insulation of up to 200 mm, but also the accumulation and thus the thermal inertia of the walls several times higher than conventional building materials.
This combination allows you to accumulate heat from sunlight through glazed areas during the day and in the evening return it back into the living space. This has a reverse effect in the summer where accumulated evening and night time cold air helps maintain a pleasant room temperature without additional air conditioning.
When referring to VELOX building systems, the term "standard" does not represent anything other than top quality and excellent features. This of course also applies to the components of a standard wall.
Business signs Wall Construction |
The thickness of the walls without plaster t mm |
Using a thickness beat.insulation (polystyrene foam) mm |
Thermal resistance (ČSN 73 0540) R (wall without plaster) m 2 K / W |
Heat transfer coefficient U (wall without plaster) W / m 2 K |
Index of air flak sonority R W (wall with plaster) dB |
YL 34 plus WS-EPS-plus 155/150/WS 35 |
340 | outer wall with 120 mm insulation | 4.39 | 0.22 | 51 |
YL 34 WS-35 EPS 155/150/WS |
340 | outer wall with 120 mm insulation | 4,092 | 0,235 | 51 |
UL 32 WS-35 EPS 135/150/WS |
320 | outer wall with 100 mm insulation | 3,536 | 0,270 | 51 |
OL 30 WS-35 EPS 115/150/WS |
300 | outer wall with 80 mm insulation | 2,981 | 0,318 | 51 |
EL 27 WS-35 EPS 85/150/WS |
270 | outer wall with 50 mm insulation | 2,150 | 0,430 | 52 |
LL 22 35 WS 35/150/WS |
220 | external load bearing wall, basement wall | 0.76 | 1.08 | 57 |
L 7.5 GG 10 WS 75 WS 50 50/WS |
75 100 |
partition | 0.79 0.90 |
0,952 0,862 |
39 39 |
The supporting wall of terraced houses or flats TT 19 double - the rate of silencing Rw = 77 db.
Load bearing partition walls without reinforcement to the quality of the concrete C 12/15 to C 25/30, with plaster on both sides with a thickness of 15 mm.
Thickness mm | Density kg/m2 | Thermal conductivity W/mK | Partial resistance m2K/W | |
Plaster | 15 | 1600 | 0,60 | 0,025 |
VELOX WSD | 35 | 750 | 0,13 | 0,270 |
Concrete core | 120 | 2200 | 1,23 | 0,100 |
VELOX WSD | 35 | 750 | 0,13 | 0,270 |
Mineral wool insulation | 30 | 105 | 0,04 | 0,750 |
VELOX WSD | 35 | 750 | 0,13 | 0,270 |
Concrete core | 120 | 2200 | 1,23 | 0,100 |
VELOX WSD | 35 | 750 | 0,13 | 0,270 |
Plaster | 15 | 1600 | 0,60 | 0,025 |
Weight of construction KG/M2 - 440
Thermal resistance overall wall make up M2/KW - 1,81
Heat transfer coefficient of the whole structure W/M2K - 0,55

Load bearing wall between flats GT 30 - the level of silencing Rw = 64Db.
Load bearing partition walls without reinforcement to the quality of concrete C 12/15 to C 25/30 and with plaster on both sides, with a thickness of 15 mm.
It is possible to build up to 15 storys / levels, depending on the structural analysis.
Thickness mm | Density kg/m2 | Thermal conductivity W/mK | Partial resistance m2K/W | |
Plaster | 15 | 1600 | 0,60 | 0,025 |
VELOX WS | 50 | 630 | 0,11 | 0,455 |
Concrete core | 215 | 2100 | 1,23 | 0,175 |
VELOX WSD | 35 | 750 | 0,15 | 0,233 |
Plaster | 15 | 1600 | 0,60 | 0,025 |
Weight of construction KG/M2 - 557
Thermal resistance overall wall make up M2/KW - 0,913
Heat transfer coefficient of the whole structure W/M2K - 0,853

Load bearing wall between flats TT 30 - the level of silencing Rw = 63Db
Load bearing partition wall without reinforcement to the quality of concrete C 12/15 to C 25/30 and with plaster on both sides with a thickness of 15 mm.
It is possible to build up to 12 storeys / levels, depending on the structural analysis.
Thickness mm | Density kg/m2 | Thermal conductivity W/mK | Partial resistance m2K/W | |
Plaster | 15 | 1600 | 0,60 | 0,025 |
VELOX WS | 35 | 750 | 0,15 | 0,233 |
Concrete core | 230 | 2100 | 1,23 | 0,187 |
VELOX WSD | 35 | 750 | 0,15 | 0,233 |
Plaster | 15 | 1600 | 0,60 | 0,025 |
Weight of construction KG/M2 - 584
Thermal resistance overall wall make up M2/KW - 0,704
Heat transfer coefficient of the whole structure W/M2K - 1,038

Load beaarring wall between flats TT 25 - the level of silencing Rw = 60db
Load barring partition wall without reinforcement to the quality of concrete C 12/15 to C 25/30 and with plaster on both sides, with a thickness of 15 mm.
It is possible to build up to 12 storeys / levels, depending on the structural analysis.
Thickness mm | Density kg/m2 | Thermal conductivity W/mK | Partial resistance m2K/W | |
Plaster | 15 | 1600 | 0,60 | 0,025 |
VELOX WS | 35 | 750 | 0,15 | 0,233 |
Concrete core | 180 | 2100 | 1,23 | 0,146 |
VELOX WSD | 35 | 750 | 0,15 | 0,233 |
Plaster | 15 | 1600 | 0,60 | 0,025 |
Weight of construction KG/M2 - 479
Thermal resistance overall wall make up M2/KW - 0,663
Heat transfer coefficient of the whole structure W/M2K - 1,038